Bug 585687 - monitor layout should be 'normalized' after each drag'n'drop operation
monitor layout should be 'normalized' after each drag'n'drop operation
Status: RESOLVED FIXED
Product: gnome-control-center
Classification: Core
Component: Display
2.26.x
Other All
: Normal normal
: ---
Assigned To: Control-Center Maintainers
Control-Center Maintainers
3.10
Depends on:
Blocks:
 
 
Reported: 2009-06-13 21:54 UTC by Andreas Schildbach
Modified: 2013-09-03 10:30 UTC
See Also:
GNOME target: ---
GNOME version: 2.25/2.26



Description Andreas Schildbach 2009-06-13 21:54:37 UTC
Please describe the problem:
Currently, you can drag monitors out of visible space quite easily, and they would never come back so you can't drag them any more.

To fix this, I'd propose to normalize (fit to view) the monitor layout after each drag'n'drop operation rather than just at application start.


Steps to reproduce:


Actual results:


Expected results:


Does this happen every time?


Other information:
Comment 1 Federico Mena Quintero 2009-07-16 22:30:44 UTC
This is probably just a question of calling gnome_rr_config_sanitize() when the button is released.
Comment 2 Federico Mena Quintero 2009-07-16 22:32:24 UTC
This bug is also in https://bugzilla.novell.com/show_bug.cgi?id=381026
Comment 3 Thomas Wood 2013-09-03 10:30:27 UTC
This was fixed in version 3.8.4 (commit 9dc2ac7) and 3.9.5 (commit 30f5909).