GNOME Bugzilla – Bug 340389
gnopernicus starts always magnifier in the right part of screen
Last modified: 2006-05-10 10:44:29 UTC
If zoomer placement is not correct, gnopernicus starts the magnifier in the rigth part of screen.
Created attachment 64656 [details] [review] proposed patch
What are the issues related with the patch that it's not commited yet?
If a coordinate is ouside the screen, then "all" the coordinates are considered wrong, and magnifier is moved to the right part of screen. Instead of that, the patch clamps the coordinates to the screen.
Comment on attachment 64656 [details] [review] proposed patch patch applied on cvs head.
Comment on attachment 64656 [details] [review] proposed patch patch applied on gnome-2-14 branch.